Opcode1 | Instruction | Op/En | 64-Bit Mode | Compat/Leg Mode | Description |
---|---|---|---|---|---|
0F 01 /0 | SGDT m | M | Valid | Valid | Store GDTR to m. |
NOTES:
1. See the IA-32 Architecture Compatibility section below.
Op/En | Operand 1 | Operand 2 | Operand 3 | Operand 4 |
---|---|---|---|---|
M | ModRM:r/m (w) | N/A | N/A | N/A |
Stores the content of the global descriptor table register (GDTR) in the destination operand. The destination operand specifies a memory location.
In legacy or compatibility mode, the destination operand is a 6-byte memory location. If the operand-size attribute is 16 or 32 bits, the 16-bit limit field of the register is stored in the low 2 bytes of the memory location and the 32-bit base address is stored in the high 4 bytes.
In 64-bit mode, the operand size is fixed at 8+2 bytes. The instruction stores an 8-byte base and a 2-byte limit.
SGDT is useful only by operating-system software. However, it can be used in application programs without causing an exception to be generated if CR4.UMIP = 0. See “LGDT/LIDT—Load Global/Interrupt Descriptor Table Register” in Chapter 3, Intel® 64 and IA-32 Architectures Software Developer’s Manual, Volume 2A, for information on loading the GDTR and IDTR.
The 16-bit form of the SGDT is compatible with the Intel 286 processor if the upper 8 bits are not referenced. The Intel 286 processor fills these bits with 1s; processor generations later than the Intel 286 processor fill these bits with 0s.
IF instruction is SGDT IF OperandSize =16 or OperandSize = 32 (* Legacy or Compatibility Mode *) THEN DEST[0:15] := GDTR(Limit); DEST[16:47] := GDTR(Base); (* Full 32-bit base address stored *) FI; ELSE (* 64-bit Mode *) DEST[0:15] := GDTR(Limit); DEST[16:79] := GDTR(Base); (* Full 64-bit base address stored *) FI; FI;
None.
#UD | If the LOCK prefix is used. |
#GP(0) |
If the destination is located in a non-writable segment. If a memory operand effective address is outside the CS, DS, ES, FS, or GS segment limit. If the DS, ES, FS, or GS register is used to access memory and it contains a NULL segment selector. If CR4.UMIP = 1 and CPL > 0. |
#SS(0) | If a memory operand effective address is outside the SS segment limit. |
#PF(fault-code) | If a page fault occurs. |
#AC(0) | If alignment checking is enabled and an unaligned memory reference is made while CPL = 3. |
#UD | If the LOCK prefix is used. |
#GP | If a memory operand effective address is outside the CS, DS, ES, FS, or GS segment limit. |
#SS | If a memory operand effective address is outside the SS segment limit. |
#UD | If the LOCK prefix is used. |
#GP(0) |
If a memory operand effective address is outside the CS, DS, ES, FS, or GS segment limit. If CR4.UMIP = 1. |
#SS(0) | If a memory operand effective address is outside the SS segment limit. |
#PF(fault-code) | If a page fault occurs. |
#AC(0) | If alignment checking is enabled and an unaligned memory reference is made. |
Same exceptions as in protected mode.
#SS(0) | If a memory address referencing the SS segment is in a non-canonical form. |
#UD | If the LOCK prefix is used. |
#GP(0) |
If the memory address is in a non-canonical form. If CR4.UMIP = 1 and CPL > 0. |
#PF(fault-code) | If a page fault occurs. |
#AC(0) | If alignment checking is enabled and an unaligned memory reference is made while CPL = 3. |